Description
|
500 GPD Reverse Osmosis System
|
| |
- Two 2.5" x 21" TFC membranes
- 3.2 GPM brass rotary vane pump, coupled directly to the motor
- 1/2 HP motor - 110 Volts 60 Hertz or 220 Volts 50 Hertz.
- Aluminum frame, white powder coated, corrosion resistant, and light weight.
- One 4.5" x 10" 5 micron sediment and one 4.5" x 10" carbon block pre-filters.
- One 2.5" 0-300 psi panel gauge and two 1.5" 0-160 psi top mount gauges
- Low pressure switch - (Safety device to protect the pump from running dry).
- Solenoid valve with manual override. 110 Volt 60 Hertz, or 220 Volt 50 Hertz.
- One 1/4" brass needle manual flush valve - Regulates the product to waste ratio (system recovery)
- Manual on/off switch
|
|
|
|
System Specifications
|
|
Design
|
Vertical
|
|
Gallons Per Day
|
500 @ 70 F
|
|
Dimensions (Approx.)
|
14" x 20" x 27"
|
|
Weight (Approx.)
|
65 lbs.
|
|
Concentrate Re-Circulate
|
Optional
|
|
Auto Flush
|
N/A
|
|
Element Size (in.)
|
2521 TFC HF1
|
|
Elements (Qty.)
|
2
|
|
Motor HP
|
1/3
|
|
Voltage
|
110 or 220 Volts AC
|
|
Hertz
|
60 or 50 cycle
|
|
Feed Connection
|
3/4"
|
|
Product Connection
|
3/8"
|
|
Waste Connection
|
3/8"
|
|
|
| |
|
Operating Specifications
|
|
Minimum Feed Pressure
|
35 psi
|
|
Minimum NaCl - % Rejection
|
96%
|
|
Minimum Feed (GPM)
|
1.5
|
|
Maximum Hardness
|
15 Grains / Gallon
|
|
Maximum TDS
|
2000 ppm
|
|
Operating Pressure
|
150 psi
|
|
Maximum NaCl - % Rejection
|
98.5%
|
|
Maximum Feed (GPM)
|
3
|
|
pH Range
|
3 - 11
|
|
Maximum Temperature
|
1050 F
|
|
|
|
|
|
|
|
| Membrane: Two 2.5" x 21" TFC HF1 Membranes, For maximum rejection of impurities and high flow.Membrane Housing: Two 2.5" x 21" Champ membrane housings, Features a patented design and requires no tools for servicing.Pump: One 401 Fluid-O-Tech 2.3 GPM brass rotary vane pump, Directly couples to the motor, and designed for continuous high pressures.Motor: One 1/3 HP GE motor, 110 or 220 Volts AC, 60 or 50 hertz.Frame: Aluminum, White Powder Coated, Corrosion resistant, and light weight.Sediment Filter: One 4.5" x 10" Big White 5 micron sediment filter, Removes sediments and protects the system.Carbon Block: One 4.5" x 10" Big White 10 micron carbon block, Removes chlorine, odor, and taste from incoming feed water.Filter Housing: Two 4.5" x 10" Big Grey double O-ring filter housings, Offers durability and improved sealing capabilities.Pressure Gauges: One 2.5" Gauge, 0-300 PSI, Panel Mounted Glycerin filled, and Two 1.5" Gauge, 0-160 PSI, top mount dry gauges, For monitoring the system's operating pressure, the filter and carbon operating pressure.Low Pressure Switch: One McCann's Low Pressure Switch, Safety device to protect the pump from running dry when there is insufficient feed water pressure.Solenoid Valve: One Solenoid Valve with manual override, 110 or 220 Volts AC, 60 or 50 hertz, Assists with the on/off functionality of the system.Manual Flush Valve: One 1/4" brass needle valve, Regulates the product to waste ratio (systems recovery).Switch: One manual on/off Switch.Easy Maintenance & Operation: feature a compact design and have all of their components strategically located for easy access and inspection.Optional Features Stainless Steel Housings: Two 2.5” x 21” PuroTech stainless steel membrane housings, 3/8” FNPT. High Pressure Switch: One Square D high pressure switch, Automatically starts when the tank pressure falls below 40 psi, and stops when the pressure reaches 60 psi. TDS Meter: One panel mount TDS meter, provides you with accurate readings of the feed and product water quality. Float Switch: One mechanical float switch, For atmospheric storage tank applications. Flow Meters: One Product (0-2 GPM) & one waste (0-5 GPM) flow meters, enables operator to accurately adjust product to waste ratio and monitor systems performance. Concentrate Re-Circulate: This feature offers a higher recovery rate for the system by taking a percentage of the waste water and feeding it back into the system. |
|
|
|
|
| |
- Additional cost will apply to listed price for custom modification based on water laboratory test report.
|
| |
|
|